A script that collects detailed hardware data and saves it to a file inventory.info. The script will collect information using utilities such as lshw, lsblk, lscpu, lspci, lsusb, and df.
-
- Create a file, for example: collect_inventory
- Put in it a code below
- Save the file
- Give a right to exec (chmod +x collect_inventory)
- Run it (sudo ./collect_inventory)
#!/bin/bash
# File for saving data
OUTPUT_FILE="inventory.info"
# Create or clean up the file
> $OUTPUT_FILE
# A function for collecting and writing data to a file
collect_data() {
echo "Collecting hardware information..."
echo "### Hardware Information ###" >> $OUTPUT_FILE
echo -e "\n--- General Information ---" >> $OUTPUT_FILE
uname -a >> $OUTPUT_FILE
echo -e "\n--- CPU Information ---" >> $OUTPUT_FILE
lscpu >> $OUTPUT_FILE
echo -e "\n--- Memory Information ---" >> $OUTPUT_FILE
free -h >> $OUTPUT_FILE
echo -e "\n--- Block Devices ---" >> $OUTPUT_FILE
lsblk >> $OUTPUT_FILE
echo -e "\n--- Disk Usage ---" >> $OUTPUT_FILE
df -h >> $OUTPUT_FILE
echo -e "\n--- PCI Devices ---" >> $OUTPUT_FILE
lspci >> $OUTPUT_FILE
echo -e "\n--- USB Devices ---" >> $OUTPUT_FILE
lsusb >> $OUTPUT_FILE
echo -e "\n--- Network Interfaces ---" >> $OUTPUT_FILE
ip a >> $OUTPUT_FILE
echo -e "\n--- Detailed Hardware Information ---" >> $OUTPUT_FILE
lshw -short >> $OUTPUT_FILE
echo "Data collection complete. Saved to $OUTPUT_FILE."
}
# We check the availability of the necessary utilities & collect data
if command -v lshw &> /dev/null && command -v lsblk &> /dev/null && \
command -v lscpu &> /dev/null && command -v lspci &> /dev/null && \
command -v lsusb &> /dev/null && command -v df &> /dev/null; then
collect_data
else
echo "Error: One or more required utilities are not installed."
exit 1
fi
# Example output
### Hardware Information ###
--- General Information ---
Linux host-06 5.4.0-187-generic #207-Ubuntu SMP Mon Jun 10 08:16:10 UTC 2024 x86_64 x86_64 x86_64 GNU/Linux
--- CPU Information ---
Architecture: x86_64
CPU op-mode(s): 32-bit, 64-bit
Byte Order: Little Endian
Address sizes: 46 bits physical, 48 bits virtual
CPU(s): 32
On-line CPU(s) list: 0-31
Thread(s) per core: 2
Core(s) per socket: 8
Socket(s): 2
NUMA node(s): 2
Vendor ID: GenuineIntel
CPU family: 6
Model: 79
Model name: Intel(R) Xeon(R) CPU E5-2620 v4 @ 2.10GHz
Stepping: 1
CPU MHz: 1199.641
CPU max MHz: 3000.0000
CPU min MHz: 1200.0000
BogoMIPS: 4197.51
Virtualization: VT-x
L1d cache: 512 KiB
L1i cache: 512 KiB
L2 cache: 4 MiB
L3 cache: 40 MiB
NUMA node0 CPU(s): 0-7,16-23
NUMA node1 CPU(s): 8-15,24-31
Vulnerability Gather data sampling: Not affected
Vulnerability Itlb multihit: KVM: Mitigation: Split huge pages
Vulnerability L1tf: Mitigation; PTE Inversion; VMX conditional cache flushes, SMT vulnerable
Vulnerability Mds: Mitigation; Clear CPU buffers; SMT vulnerable
Vulnerability Meltdown: Mitigation; PTI
Vulnerability Mmio stale data: Mitigation; Clear CPU buffers; SMT vulnerable
Vulnerability Retbleed: Not affected
Vulnerability Spec store bypass: Mitigation; Speculative Store Bypass disabled via prctl and seccomp
Vulnerability Spectre v1: Mitigation; usercopy/swapgs barriers and __user pointer sanitization
Vulnerability Spectre v2: Mitigation; Retpolines; IBPB conditional; IBRS_FW; STIBP conditional; RSB filling; PBRSB-eIBRS Not affected; BHI Not affected
Vulnerability Srbds: Not affected
Vulnerability Tsx async abort: Mitigation; Clear CPU buffers; SMT vulnerable
Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch cpuid_fault epb cat_l3 cdp_l3 invpcid_single pti intel_ppin ssbd ibrs ibpb stibp tpr_shadow vnmi flexpriority ept vpid ept_ad fsgsbase tsc_adjust bmi1 hle avx2 smep bmi2 erms invpcid rtm cqm rdt_a rdseed adx smap intel_pt xsaveopt cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts md_clear flush_l1d
--- Memory Information ---
total used free shared buff/cache available
Mem: 157Gi 33Gi 30Gi 2.0Mi 93Gi 122Gi
Swap: 8.0Gi 2.0Mi 8.0Gi
--- Block Devices ---
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
loop0 7:0 0 55.7M 1 loop /snap/core18/2823
loop1 7:1 0 55.7M 1 loop /snap/core18/2829
loop2 7:2 0 64M 1 loop /snap/core20/2264
loop3 7:3 0 38.8M 1 loop /snap/snapd/21465
loop4 7:4 0 38.8M 1 loop /snap/snapd/21759
loop5 7:5 0 91.9M 1 loop /snap/lxd/24061
loop6 7:6 0 71.3M 1 loop /snap/lxd/16099
loop7 7:7 0 64M 1 loop /snap/core20/2318
sda 8:0 0 465.8G 0 disk
├─sda1 8:1 0 1M 0 part
└─sda2 8:2 0 465.8G 0 part /
sdb 8:16 0 931.5G 0 disk
└─sdb1 8:17 0 931.5G 0 part /big-disk
sdc 8:32 0 931.5G 0 disk
└─md0 9:0 0 931.4G 0 raid1 /raid
sdd 8:48 0 931.5G 0 disk
└─md0 9:0 0 931.4G 0 raid1 /raid
sde 8:64 0 931.5G 0 disk
└─md2 9:2 0 931.4G 0 raid1 /raid-2
sdf 8:80 0 931.5G 0 disk
└─md2 9:2 0 931.4G 0 raid1 /raid-2
--- Disk Usage ---
Filesystem Size Used Avail Use% Mounted on
udev 79G 0 79G 0% /dev
tmpfs 16G 2.3M 16G 1% /run
/dev/sda2 458G 213G 222G 50% /
tmpfs 79G 0 79G 0% /dev/shm
tmpfs 5.0M 0 5.0M 0% /run/lock
tmpfs 79G 0 79G 0% /sys/fs/cgroup
/dev/sdb1 916G 34G 836G 4% /big-disk
/dev/md0 916G 419G 452G 49% /raid
/dev/md2 916G 28K 870G 1% /raid-2
/dev/loop0 56M 56M 0 100% /snap/core18/2823
/dev/loop1 56M 56M 0 100% /snap/core18/2829
/dev/loop2 64M 64M 0 100% /snap/core20/2264
/dev/loop4 39M 39M 0 100% /snap/snapd/21759
/dev/loop3 39M 39M 0 100% /snap/snapd/21465
/dev/loop6 72M 72M 0 100% /snap/lxd/16099
/dev/loop5 92M 92M 0 100% /snap/lxd/24061
/dev/loop7 64M 64M 0 100% /snap/core20/2318
tmpfs 16G 0 16G 0% /run/user/1000
--- PCI Devices ---
00:00.0 Host bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DMI2 (rev 01)
00:01.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1 (rev 01)
00:02.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2 (rev 01)
00:03.0 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:03.2 PCI bridge: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3 (rev 01)
00:04.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 0 (rev 01)
00:04.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 1 (rev 01)
00:04.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 2 (rev 01)
00:04.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 3 (rev 01)
00:04.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 4 (rev 01)
00:04.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 5 (rev 01)
00:04.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 6 (rev 01)
00:04.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 7 (rev 01)
00:05.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management (rev 01)
00:05.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug (rev 01)
00:05.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors (rev 01)
00:05.4 PIC: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC (rev 01)
00:11.0 Unassigned class [ff00]: Intel Corporation C610/X99 series chipset SPSR (rev 05)
00:11.4 SATA controller: Intel Corporation C610/X99 series chipset sSATA Controller [AHCI mode] (rev 05)
00:14.0 USB controller: Intel Corporation C610/X99 series chipset USB xHCI Host Controller (rev 05)
00:16.0 Communication controller: Intel Corporation C610/X99 series chipset MEI Controller #1 (rev 05)
00:16.1 Communication controller: Intel Corporation C610/X99 series chipset MEI Controller #2 (rev 05)
00:1a.0 USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #2 (rev 05)
00:1c.0 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #1 (rev d5)
00:1c.4 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #5 (rev d5)
00:1c.5 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #6 (rev d5)
00:1c.7 PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #8 (rev d5)
00:1d.0 USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #1 (rev 05)
00:1f.0 ISA bridge: Intel Corporation C610/X99 series chipset LPC Controller (rev 05)
00:1f.2 SATA controller: Intel Corporation C610/X99 series chipset 6-Port SATA Controller [AHCI mode] (rev 05)
00:1f.3 SMBus: Intel Corporation C610/X99 series chipset SMBus Controller (rev 05)
02:00.0 RAID bus controller: Broadcom / LSI MegaRAID SAS-3 3108 [Invader] (rev 02)
06:00.0 Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
07:00.0 Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
08:00.0 PCI bridge: ASPEED Technology, Inc. AST1150 PCI-to-PCI Bridge (rev 03)
09:00.0 VGA compatible controller: ASPEED Technology, Inc. ASPEED Graphics Family (rev 30)
7f:08.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
7f:08.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
7f:08.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
7f:09.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
7f:09.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
7f:09.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
7f:0b.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
7f:0b.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
7f:0b.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
7f:0b.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug (rev 01)
7f:0c.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0c.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0f.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0f.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0f.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0f.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:0f.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
7f:10.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 01)
7f:10.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 01)
7f:10.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
7f:10.6 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
7f:10.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
7f:12.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 01)
7f:12.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 01)
7f:13.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 01)
7f:13.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 01)
7f:13.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
7f:13.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
7f:13.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
7f:13.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
7f:13.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast (rev 01)
7f:13.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 01)
7f:14.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control (rev 01)
7f:14.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control (rev 01)
7f:14.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error (rev 01)
7f:14.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error (rev 01)
7f:14.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
7f:14.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
7f:14.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
7f:14.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
7f:15.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control (rev 01)
7f:15.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control (rev 01)
7f:15.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error (rev 01)
7f:15.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error (rev 01)
7f:16.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Target Address/Thermal/RAS (rev 01)
7f:16.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Broadcast (rev 01)
7f:16.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 01)
7f:17.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Thermal Control (rev 01)
7f:17.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
7f:17.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
7f:17.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
7f:17.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
7f:1e.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1e.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1e.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1e.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1e.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1f.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
7f:1f.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
80:04.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 0 (rev 01)
80:04.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 1 (rev 01)
80:04.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 2 (rev 01)
80:04.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 3 (rev 01)
80:04.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 4 (rev 01)
80:04.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 5 (rev 01)
80:04.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 6 (rev 01)
80:04.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 7 (rev 01)
80:05.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management (rev 01)
80:05.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug (rev 01)
80:05.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors (rev 01)
80:05.4 PIC: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC (rev 01)
ff:08.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
ff:08.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
ff:08.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0 (rev 01)
ff:09.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
ff:09.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
ff:09.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1 (rev 01)
ff:0b.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
ff:0b.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
ff:0b.2 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1 (rev 01)
ff:0b.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug (rev 01)
ff:0c.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0c.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0f.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0f.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0f.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0f.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:0f.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent (rev 01)
ff:10.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 01)
ff:10.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent (rev 01)
ff:10.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
ff:10.6 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
ff:10.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox (rev 01)
ff:12.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 01)
ff:12.1 Performance counters: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0 (rev 01)
ff:13.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 01)
ff:13.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS (rev 01)
ff:13.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
ff:13.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
ff:13.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
ff:13.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder (rev 01)
ff:13.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast (rev 01)
ff:13.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 01)
ff:14.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control (rev 01)
ff:14.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control (rev 01)
ff:14.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error (rev 01)
ff:14.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error (rev 01)
ff:14.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
ff:14.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
ff:14.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
ff:14.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface (rev 01)
ff:15.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control (rev 01)
ff:15.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control (rev 01)
ff:15.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error (rev 01)
ff:15.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error (rev 01)
ff:16.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Target Address/Thermal/RAS (rev 01)
ff:16.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Broadcast (rev 01)
ff:16.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast (rev 01)
ff:17.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Thermal Control (rev 01)
ff:17.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.5 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.6 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:17.7 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface (rev 01)
ff:1e.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.1 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.3 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1e.4 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1f.0 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
ff:1f.2 System peripheral: Intel Corporation Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit (rev 01)
--- USB Devices ---
Bus 002 Device 002: ID 8087:8002 Intel Corp.
Bus 002 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
Bus 001 Device 002: ID 8087:800a Intel Corp.
Bus 001 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
Bus 004 Device 001: ID 1d6b:0003 Linux Foundation 3.0 root hub
Bus 003 Device 003: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port
Bus 003 Device 002: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port
Bus 003 Device 001: ID 1d6b:0002 Linux Foundation 2.0 root hub
--- Network Interfaces ---
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 127.0.0.1/8 scope host lo
valid_lft forever preferred_lft forever
inet6 ::1/128 scope host
valid_lft forever preferred_lft forever
2: eno1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc mq state UP group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
inet xxx.xxx.xx.xxx/24 brd xxx.xxx.xx.xxx scope global eno1
valid_lft forever preferred_lft forever
inet6 xxxx::xxxx:xxx:xxxx:xxxx/64 scope link
valid_lft forever preferred_lft forever
3: eno2: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master br0 state UP group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
4: br0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc noqueue state UP group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
inet xxx.xxx.xx.xx/24 brd xxx.xxx.xx.xxx scope global dynamic br0
valid_lft 1661sec preferred_lft 1661sec
inet6 xxxx::xxxx:xxx:xxxx:xxxx/64 scope link
valid_lft forever preferred_lft forever
5: virbr0: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc noqueue state DOWN group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
inet xxx.xxx.xxx.xx/24 brd xxx.xxx.xxx.255 scope global virbr0
valid_lft forever preferred_lft forever
6: virbr0-nic: <BROADCAST,MULTICAST> mtu 1500 qdisc fq_codel master virbr0 state DOWN group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
7: vnet0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc fq_codel master br0 state UNKNOWN group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
inet6 xxxx::xxxx:xx:xxxx:xxxx/64 scope link
valid_lft forever preferred_lft forever
10: vnet1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 9000 qdisc fq_codel master br0 state UNKNOWN group default qlen 1000
link/ether xx:xx:xx:xx:xx:xx brd ff:ff:ff:ff:ff:ff
inet6 xxxx::xxxx:xx:xxxx:xxxx/64 scope link
valid_lft forever preferred_lft forever
--- Detailed Hardware Information ---
H/W path Device Class Description
=======================================================
system ThinkServer RD350 (LENOVO_MT_ND)
/0 bus ThinkServer RD350
/0/0 memory 64KiB BIOS
/0/2c memory 160GiB System Memory
/0/2c/0 memory 16GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/1 memory 16GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/2 memory [empty]
/0/2c/3 memory [empty]
/0/2c/4 memory [empty]
/0/2c/5 memory [empty]
/0/2c/6 memory [empty]
/0/2c/7 memory [empty]
/0/2c/8 memory 32GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/9 memory 32GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/a memory 32GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/b memory 32GiB DIMM DDR4 Synchronous 2400 MHz (0.4 ns)
/0/2c/c memory [empty]
/0/2c/d memory [empty]
/0/2c/e memory [empty]
/0/2c/f memory [empty]
/0/46 memory 512KiB L1 cache
/0/47 memory 2MiB L2 cache
/0/48 memory 20MiB L3 cache
/0/49 processor Intel(R) Xeon(R) CPU E5-2620 v4 @ 2.10GHz
/0/4a memory 512KiB L1 cache
/0/4b memory 2MiB L2 cache
/0/4c memory 20MiB L3 cache
/0/4d processor Intel(R) Xeon(R) CPU E5-2620 v4 @ 2.10GHz
/0/100 bridge Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DMI2
/0/100/1 bridge Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 1
/0/100/2 bridge Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 2
/0/100/2/0 storage MegaRAID SAS-3 3108 [Invader]
/0/100/3 bridge Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3
/0/100/3.2 bridge Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D PCI Express Root Port 3
/0/100/4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 0
/0/100/4.1 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 1
/0/100/4.2 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 2
/0/100/4.3 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 3
/0/100/4.4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 4
/0/100/4.5 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 5
/0/100/4.6 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 6
/0/100/4.7 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 7
/0/100/5 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management
/0/100/5.1 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug
/0/100/5.2 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors
/0/100/5.4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC
/0/100/11 generic C610/X99 series chipset SPSR
/0/100/11.4 storage C610/X99 series chipset sSATA Controller [AHCI mode]
/0/100/14 bus C610/X99 series chipset USB xHCI Host Controller
/0/100/14/0 usb3 bus xHCI Host Controller
/0/100/14/0/6 generic USB-Serial Controller
/0/100/14/0/7 generic USB-Serial Controller
/0/100/14/1 usb4 bus xHCI Host Controller
/0/100/16 communication C610/X99 series chipset MEI Controller #1
/0/100/16.1 communication C610/X99 series chipset MEI Controller #2
/0/100/1a bus C610/X99 series chipset USB Enhanced Host Controller #2
/0/100/1a/1 usb1 bus EHCI Host Controller
/0/100/1a/1/1 bus USB hub
/0/100/1c bridge C610/X99 series chipset PCI Express Root Port #1
/0/100/1c.4 bridge C610/X99 series chipset PCI Express Root Port #5
/0/100/1c.4/0 eno1 network I210 Gigabit Network Connection
/0/100/1c.5 bridge C610/X99 series chipset PCI Express Root Port #6
/0/100/1c.5/0 eno2 network I210 Gigabit Network Connection
/0/100/1c.7 bridge C610/X99 series chipset PCI Express Root Port #8
/0/100/1c.7/0 bridge AST1150 PCI-to-PCI Bridge
/0/100/1c.7/0/0 display ASPEED Graphics Family
/0/100/1d bus C610/X99 series chipset USB Enhanced Host Controller #1
/0/100/1d/1 usb2 bus EHCI Host Controller
/0/100/1d/1/1 bus USB hub
/0/100/1f bridge C610/X99 series chipset LPC Controller
/0/100/1f.2 storage C610/X99 series chipset 6-Port SATA Controller [AHCI mode]
/0/100/1f.3 bus C610/X99 series chipset SMBus Controller
/0/1 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/2 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/3 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/6 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/7 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/8 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/9 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug
/0/d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/10 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/11 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/12 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/13 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/14 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/15 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/16 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/17 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/18 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/19 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/1a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent
/0/1b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent
/0/1c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/1d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/1e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/1f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0
/0/20 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0
/0/21 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS
/0/22 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS
/0/23 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/24 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/25 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/26 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/27 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast
/0/28 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast
/0/29 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control
/0/2a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control
/0/2b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error
/0/2d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error
/0/2e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/2f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/30 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/31 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/32 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control
/0/33 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control
/0/34 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error
/0/35 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error
/0/36 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Target Address/Thermal/RAS
/0/37 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Broadcast
/0/38 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast
/0/39 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Thermal Control
/0/3a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/3b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/3c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/3d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/3e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/3f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/40 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/41 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/42 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/43 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/44 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 0
/0/4.1 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 1
/0/4.2 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 2
/0/4.3 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 3
/0/4.4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 4
/0/4.5 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 5
/0/4.6 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 6
/0/4.7 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Crystal Beach DMA Channel 7
/0/5 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Map/VTd_Misc/System Management
/0/5.1 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO Hot Plug
/0/5.2 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D IIO RAS/Control Status/Global Errors
/0/5.4 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D I/O APIC
/0/45 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/4e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/4f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 0
/0/50 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/51 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/52 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D QPI Link 1
/0/53 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/54 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/55 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link 0/1
/0/56 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R3 QPI Link Debug
/0/57 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/58 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/59 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/5f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/60 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/61 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/62 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/63 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Caching Agent
/0/64 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent
/0/65 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D R2PCIe Agent
/0/66 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/67 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/68 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Ubox
/0/69 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0
/0/6a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Home Agent 0
/0/6b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS
/0/6c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Target Address/Thermal/RAS
/0/6d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/6e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/6f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/70 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel Target Address Decoder
/0/71 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Broadcast
/0/72 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast
/0/73 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Thermal Control
/0/74 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Thermal Control
/0/75 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 0 Error
/0/76 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 1 Error
/0/77 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/78 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/79 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/7a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 0/1 Interface
/0/7b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Thermal Control
/0/7c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Thermal Control
/0/7d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 2 Error
/0/7e generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 0 - Channel 3 Error
/0/7f generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Target Address/Thermal/RAS
/0/80 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Broadcast
/0/81 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Global Broadcast
/0/82 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Memory Controller 1 - Channel 0 Thermal Control
/0/83 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/84 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/85 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/86 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D DDRIO Channel 2/3 Interface
/0/87 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/88 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/89 generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/8a generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/8b generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/8c generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/8d generic Xeon E7 v4/Xeon E5 v4/Xeon E3 v4/Xeon D Power Control Unit
/0/8e system PnP device PNP0b00
/0/8f system PnP device PNP0c02
/0/90 system PnP device PNP0c02
/0/91 scsi0 storage
/0/91/0.2.0 /dev/sda disk 500GB Samsung SSD 870
/0/91/0.2.0/1 /dev/sda1 volume 1023KiB BIOS Boot partition
/0/91/0.2.0/2 /dev/sda2 volume 465GiB EXT4 volume
/0/91/0.3.0 /dev/sdb disk 1TB Samsung SSD 870
/0/91/0.3.0/1 /dev/sdb1 volume 931GiB EXT4 volume
/0/91/0.6.0 /dev/sdc disk 1TB Samsung SSD 870
/0/91/0.7.0 /dev/sdd disk 1TB Samsung SSD 870
/0/91/0.8.0 /dev/sde disk 1TB Samsung SSD 870
/0/91/0.9.0 /dev/sdf disk 1TB Samsung SSD 870
/1 vnet1 network Ethernet interface
/2 virbr0-nic network Ethernet interface
/3 vnet0 network Ethernet interface